External Wall Fire Risk Appraisal (PAS 9980:2026) and EWS1
F.I.R.E. Consultancy undertakes fire risk appraisals of external walls (FRAEW) using the methodology set out in PAS 9980:2026. Our work helps building owners and managers understand the fire risk associated with external wall construction and identify proportionate next steps.
Where an EWS1 form is required, the findings of the external wall assessment can support completion of the form by a suitably qualified professional. An EWS1 is principally used within the valuation and lending process. It is not a life safety certificate and does not replace the wider fire risk assessment for a building.
What is a PAS 9980 fire risk appraisal?
PAS 9980:2026 provides a methodology for fire risk appraisals of external walls (FRAEWs) for existing blocks of flats and can also be used for other residential buildings. It replaces PAS 9980:2022 and provides a structured, risk-based approach for competent professionals carrying out these assessments.
Where an FRAEW was previously completed by a competent assessor using PAS 9980:2022, current government guidance states that it should continue to be valid until it needs to be reviewed or updated. The appraisal considers the external wall as a system rather than focusing only on a single material or product.
The assessment is proportionate to the building and the information available. It can consider factors such as external wall construction, cladding and insulation, cavities and barriers, attachments such as balconies, the arrangement of the facade and the potential consequences of external fire spread.
When might an external wall assessment be required?
A fire risk appraisal of the external wall may be appropriate where the construction is uncertain, combustible materials may be present, previous information is incomplete, a fire risk assessment identifies a need for further investigation, or a lender or valuer requests information about the external wall system.
In England and Wales, the Fire Safety Act 2021 clarified that the structure and external walls of relevant multi-occupied residential buildings fall within the scope of the Regulatory Reform (Fire Safety) Order 2005.
What our assessment can include
- Review of available drawings, specifications, previous reports and building information.
- Assessment of the external wall construction and relevant attachments.
- Site inspection and investigation appropriate to the agreed scope.
- Consideration of fire spread pathways, wall configuration and relevant fire safety measures.
- Identification of information gaps or areas requiring further investigation.
- A clear report setting out the risk outcome, supporting evidence and recommended actions.
- EWS1 support where the building and purpose of the assessment make this appropriate.
Clear evidence for informed decisions
The outcome of the appraisal is intended to give clients a clearer understanding of external wall fire risk and the evidence supporting that conclusion. Where action is required, the report can help inform further investigation, mitigation, remediation planning and wider fire safety decision-making.
If you require a PAS 9980:2026 external wall fire risk appraisal or need to discuss whether an EWS1 may be appropriate, contact F.I.R.E. Consultancy to discuss your building and the information currently available.